Piezoelectric Press Force load cell, lightweight miniature force transducer, Fz max 0 … 5 kN / 9313AA1

Piezoelectric Press Force load cell, lightweight miniature force transducer, Fz max 0 … 5 kN
9313AA1
18007649
  • Preloaded and calibrated force transducer, ready to measure immediately
  • Calibrated ranges Fz: 0 … 0,05 kN, 0 … 0,5 kN, 0 … 5 kN
  • Sensitivity: ≈ –10 pC/N
  • Dimensions DxH: 13x10 mm
In Stock
On Request
Log in to myKistler to see prices
Standart Force Sensors
Maximum measuring range Fz
0 … 5 kN
Maximum Overload tension/pressure
–0.5 / 5.5 kN
Maximum shear force Fx,y that equals lateral force at the joint
0.1 kN
Maximum tightening torque Mz
0.3 Nm
Maximum bending moment Mx,y at Fz = 0%
1.3 Nm
Maximum bending moment Mx,y at Fz = 100%
0.2 Nm
Crosstalk Fx,y -> Fz
<0.29 N/N
Crosstalk Mx,y -> Fz
<72 N/N
Case material
DIN 1.4542
Connector, electrical
KIAG 10-32 neg.
Global attributes
Sensitivity
–10 pC/N
Threshold
0.01 N
Operating temperature range
-40 … 120 °C
Output signal type
TEST
Charge (Piezoelectric, PE)
Degree of protection → EN 60529
IP67 (with welded sensor), IP65 (with connected cable)
Weight (without cable)
10 g
Force Sensors (Facets)
Preloaded sensor
Preloaded sensors are already calibrated and therefore ready-to-use. Non-preloaded sensors are smaller.
Yes
Measuring range
Choose the category in which the max force value you want to measure falls in.
0 … 5 kN
Maximum measuring range
5 kN
Force sensor type
Choose the category depending on the no. of axis you want to measure. A dynamometer is a force plate measuring forces and moments.
Single axis force sensor
Dynamometers
Calibrated measuring range
0 … 5 kN (Fz 100%)
Rigidity Cz
≈0.560 kN/μm
Direct Measurement Pressure Sensors
Temperature coefficient of sensitivity
0.05 %/°C
This lightweight miniature compression force sensor is particularly suitable for measuring dynamic forces and also quasistatic forces. Preloaded and provided with practical adaptation options, the sensor is ready for immediate use. The Press Force load cell is based on the piezoelectric measuring principle. The force acting on the crystal element produces a proportional electric charge at the signal output. A measuring amplifier connected downstream to the sensor converts this charge into a process signal which can be evaluated. The particularly square shape of the sensor body and the force introduction at both ends via axial threaded bores bring advantages in special mounting situations. Tensile forces up to 10 % of the compression force range are measured. These ranges are not calibrated. However, they are often used for the detection of tool withdrawal forces, for example after press fitting processes.
Data sheet
English
pdf
Please click here to log in to myKistler and you will be redirected.
Manual
Press Force Sensor
English
pdf
Please click here to log in to myKistler and you will be redirected.
125 results