Piezoelectric Press Force load cell, press force transducer, Fz max 0 … 10 kN / 9323AA

Piezoelectric Press Force load cell, press force transducer, Fz max 0 … 10 kN
9323AA
18007666
  • Preloaded and calibrated press force transducer, ready to measure immediately
  • Calibrated ranges Fz: 0 … 0,1 kN, 0 … 1 kN, 0 … 10 kN
  • Sensitivity: ≈ –9,6 pC/N
  • Dimensions DxH: 20x26 mm
价格垂询
价格垂询
Standart Force Sensors
Maximum shear force Fx, Fy (Fz = 0)
0.62 kN
Maximum tension force
0 … -1 kN
Maximum torque Mz (Fx = 0, Fy = 0, Fz = 0)
5 Nm
Overload Fz
12 kN
Preloading force Fv
8.5 kN
Maximum bending moment Mx,y at Fz = 0%
23 Nm
Maximum bending moment Mx,y at Fz = 100%
0.9 Nm
Crosstalk Fx,y -> Fz
≤±0.05 N/N
Crosstalk Mx,y -> Fz
≤±0.5 N/Nm
Repeatability
0.03 %
Natural frequency fn(Fz)
>74.5 kHz
Rigidity Cz (Fz)
≈1.3 kN/μm
Capacity C
≈68 pF
Case material
DIN 1.4542
Global attributes
Sensitivity
–9.6 pC/N
Operating temperature range
-40 … 120 °C
Output signal type
TEST
Charge (Piezoelectric, PE)
Degree of protection → EN 60529
IP67 (with welded sensor), IP65 (with connected cable)
Insulation resistance
≥50^13 Ω
Applications
In- and end-of-line testing for production processes
Force Sensors (Facets)
Preloaded sensor
Preloaded sensors are already calibrated and therefore ready-to-use. Non-preloaded sensors are smaller.
Yes
Measuring range
Choose the category in which the max force value you want to measure falls in.
0 … 10 kN
Maximum measuring range
10 kN
Force sensor type
Choose the category depending on the no. of axis you want to measure. A dynamometer is a force plate measuring forces and moments.
Single axis force sensor
Dynamometers
Calibrated measuring range
0 … 10 kN (Fz 100%)
Direct Measurement Pressure Sensors
Temperature coefficient of sensitivity
0.05 %/°C
This force transducer of the Press Force series is ideal for measuring both dynamic and quasistatic forces. The factory preloading and adaptability of these practical designs ensure readiness for immediate use. The Press Force load cell is based on the piezoelectric measuring principle. The force acting on the quartz element generates at the output of the sensor a proportional electric charge, which is converted by the series-connected measuring amplifier into a process signal suitable for evaluation (typically 0 ... 10 V). Depending on the type of sensor, tension forces of up to 16 % of the compression force range can also be measured. Although uncalibrated, these ranges is often used for detecting tool withdrawal forces, for example after press-fit processes.
数据表
中文
pdf
新信息: 请点击此处登录 myKistler,您将跳转至新页面。
英语
pdf
新信息: 请点击此处登录 myKistler,您将跳转至新页面。
说明书
Press Force Sensor
英语
pdf
新信息: 请点击此处登录 myKistler,您将跳转至新页面。
126条结果
配件类型